MGE UPS Systems ESPRIT User Manual

Browse online or download User Manual for Uninterruptible power supplies (UPSs) MGE UPS Systems ESPRIT. MGE UPS Systems ESPRIT User`s manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User’s Manual

Made in USAMade in USASlim Line Rack UPSUser’s ManualModels 3 & 4www.mgeups.com

Page 2 - MGE UPS SYSTEMS

2—22C. Esprit Rack UPS Product Views With Rack KitFigure 2a. Rear View of Models 3 and 4 With Rack Kit and Extended BatteriesModel 3 Model 4 Figure 2

Page 3

3A. Storing the UPS and Recharging the BatteryAlways store the equipment in its original packaging.The battery is of the sealed lead-acid type. Batter

Page 4

3E. Connecting the Optional Extended BatteryPlug the DC battery cable into the UPS module as shown in Figure 2a. The cable plug is keyed,so make sure

Page 5 - Contents

The transistor resistance is 27 ohms and the maximum current allowed is 140mA AC or DC with ambient temperature of up to 40°C.In order to get a "

Page 6

3—4Caution: Connect only computer-type loads to the Esprit UPS. Warranty is void if non-computer-type loads are connected to the UPS.3J. Solution-Pac

Page 7 - 1. Introduction

4. Startup and Shutdown4A. UPS StartupYou are ready to start the equipment after installing the UPS module, optional battery module(s),any options, an

Page 8

4—2If desired, the UPS can be set up to operate at a known, fixed frequency regardless of thedetected utility frequency. Fixed-frequency operation is

Page 9 - (US and Canadian Models)

4—3Off Flashing On 1. Fault The UPS is operating The UPS has detected a The UPS has detected an Detected normally. No faults new operating fa

Page 10 - Rack "ears"

4—4The "Fault Detected" LED turns on and acts as described above for ANY system alarm,including those that have their own status indicators

Page 11 - 3. Installation

4—5Although six button states are detectable, not every button combination has an assigned task. buttonstates/combinations that have no assigned task

Page 12 - Figure 3d

For service call:1-800-438-7373MGE UPS SYSTEMS1660 Scenic AvenueCosta Mesa, CA 92626(714) 557-1636www.mgeups.comRevision HistoryEsprit Rack UPS User&a

Page 14 - 3J. Solution-Pac Software

5. Performance & Product Specifications5—1Table 5a. Esprit Models 3 and 4 Rack UPS SpecificationsItem Specification CommentOutput VA 2880/4000Outp

Page 15 - 4. Startup and Shutdown

Table 5a. Esprit Models 3 and 4 Rack UPS Specifications (Continued)Item Specification CommentDesign standards Safety; UL, cUL 1778, Emissions;FCC A, S

Page 16 - 4D. UPS Shutdown

6. Advanced Configuration890-=qwertyuioEsprit Front Panel Configuration Mode Usage and InstructionsFor advanced users only!The Esprit UPS is shipped f

Page 17 - Off Flashing On

6—2It is possible to cycle backward through the configuration options by pressing and holding the topbutton. A given option setting can be forced to i

Page 18 - Button Operation

6—3Options 0, 1, 2 – Extended Battery ConfigurationThese three option switches should be changed as shown in the table below when new batterycabinet(s

Page 19 - 4F. Fault Alarms

6—4Options 5, 6 – Input Voltage ToleranceUse these two option switches to select the Esprit’s sensitivity to low/high input voltage conditions.The Esp

Page 20

6—5Option 10 – Automatic UPS restart after Low Battery shutdownThe factory setting for this option is ON, which allows the UPS to automatically turn i

Page 21

6—6Option 15 – Power-On Inverter Test (POIT)When this option is set to the factory default ON setting, the Esprit will perform a short battery/invert

Page 22 - (In minutes, 0.62 PF)

7—17. Service & Maintenance7A. MaintenanceClean the UPS with a dry cloth after turning off all power to the UPS and switching off the powerswitch.

Page 23 - 6B. Using Configuration Mode

Important Safety Instructions. Save These Instructions. This manual contains important safety instructions for the Esprit Models 3 and 4 that should

Page 24 - 6C. Configuration Options

7—27B. Recycling Your UPS In USA or Canada, call 1-714-557-1636, M - F, 6:00 A.M. to 5:00 P.M. PST. Ask for a returngoods authorization for free UPS

Page 25

8—18. TroubleshootingProblem Possible causeRequired User Action◗ UPS does not turn on. ◗ UPS is not plugged in. ◗ Plug UPS into a working outlet.◗ Wal

Page 27

Other Fine MGE ProductsEclipse Surge Suppressors Ellipse300-1200 VAESV+ UPS ESV+ Rack UPS780-2200 VA 780-2200 VAEX UPS EX Rack UPS700-3000 VA 700-3000

Page 28

MGE UPS SYSTEMSUSA (headquarters)1660 Scenic AvenueCosta Mesa, CA 92626tel: (800) 523-0142(714) 557-1636fax: (714) 557-9788www.mgeups.com

Page 29 - 7. Service & Maintenance

iiCaution: Do not dispose of batteries in a fire. The batteries may explode. Do not openor mutilate the batteries. Released electrolyte is harmful to

Page 30 - 7B. Recycling Your UPS

iiiContents Quick Start ...insertImportant Safety Instructions ...

Page 31 - 8. Troubleshooting

iv6. Advanced Configuration ...6—16A. Entering/Exiting Configuration Mode ...

Page 32

1—1Thank you for your purchase of the Esprit rack"UPS" from MGE. The Esprit "UPS" will providemany years of, trouble-free power pr

Page 34

2. Getting to Know Your Esprit Rack UPS2A. Product Features & BenefitsFeatures Benefits Comments◗ Plug in operation Low installation cost◗ Modular

Comments to this Manuals

No comments