MGE UPS Systems S 3000 RT 2U User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
UPS - Evolution
Headquarters
140, avenue Jean-Kuntzmann
ZIRST - Montbonnot Saint-Martin
38334 Saint-Ismier Cedex - France
Tel.: +33 (0)4 76 18 30 00
EVOL523UK-06/06
MGE PowerServices™
2 year guarantee,
including batteries
Standard exchange of product in case
of failure, including batteries.
Associated services
(1)
:
Warranty+: 3 year extended guarantee.
1: Depending on the country, see
www.mgeups.com/services.
Communications software
and hardware
Solution-Pac software on CD-ROM
with each UPS
For monitoring the server(s) powered
by the UPS and for local and remote UPS
supervision.
Network Management Card (NMC) 2006
For connecting the UPS to an Ethernet
10/100 network, raising SNMP alarms and
supervising the UPS using a simple browser
interface.
NMC environment sensor
Monitoring the temperature, humidity
and 2 relay contacts via SNMP or HTML.
Enterprise Power Manager supervisor
For comprehensive management
of a set of UPSs using a Windows PC.
Management-Pac 2 suite
NMS integration kit: HP OpenView, IBM
Tivoli Netview, CA Unicenter, etc.
Management Card Contacts/Serial
Add a second relay contacts or Serial
port to the UPS.
UPS Control remote display
To monitor the UPS status up to 25m
from the unit.
Full user interface:
- ON/OFF button for UPS and outlets
- Load protected/ not protected LED
- Utilised power level/Battery charge level
- Status of switchable outlets
Panel for replacing batteries without
interrupting the output.
1 USB port + 1 serial port + remote
ON/OFF and emergency stop inputs.
EXB battery unit connector.
EXB units recognised automatically.
4 IEC 10A sockets, including
2 programmable sockets.
8 IEC 10A sockets, including
4 programmable sockets.
Communications card slot.
8
7
6
5
4
3
2
1
Due to developments in technical standards and the equipment described in this document, we cannot be held liable for compliance with the characteristics indicated by the images and text unless they are confirmed by us. All the brand names referred to in this document are protected by copyright.
Publication: MGE UPS SYSTEMS (June 2006) - Design and rewriting: 3c-evolution.com - Integration: Pamplemousse: +33 4 79 37 87 66 – Translation: TTP: +33 4 78 66 47 99.
* NMC card included in Netpack versions.
Part Numbers
Evolution 650 850 1150 1550 2000 S 1250 S 1750 S 2500 S 3000 S 3000
RT2U RT2U RT2U RT2U RT3U RT2U
Netpack* Netpack*
Tower 68450 68452 68454 68457 - - - - - -
Rack1U 68451 68453 68455 68458 - - - - - -
Convertible Tower/Rack
----68460 68456 68459 68463 68464 68465
EXB Models - - - - - 68470 68470 68471 68471 68471
1
2
8
5
3
4
7
1
2
3
8
6
Technical characteristics
1: Up to 40 Hz in low-sensitivity mode (programmable using Personal Solution-Pac software. 2: Adjustable to 200 V (10 % derating of output
power) / 208 V / 220 V / 230 V / 240 V. 3: USB and RS232 ports cannot be used simultaneously.
Model Evolution Evolution S
650 850 1150 1550 2000 1250 1750 2500 3000
Rating 650 VA 850 VA 1150 VA 1550 VA 2000 VA 1250 VA 1750 VA 2500 VA 3000 VA
420 W 600 W 770 W 1100 W 1600 W 1150 W 1600 W 2250 W 2700 W
Format Tower or 1U Rack RT2U (tower / rack 2U) RT2U
& RT3U
Electrical characteristics
Technology Line-Interactive High Frequency (Booster + Fader)
Input voltage and frequency 160V-294V (adjustable to 150V-294V)
ranges without using 47 to 70 Hz (50 Hz system), 56.5 to 70 Hz (60 Hz system)
(1)
batteries
Output voltage and frequency 230 V (+6/-10 %)
(2)
, 50/60 Hz +/- 0.1 %
Connections
Input 1 IEC C14 (10 A) socket
1 IEC C20 (16 A) socket
Outputs 4 IEC C13 (10 A) 8 IEC C13 (10 A)
8 IEC C13 (10 A) sockets
IEC C19 (16 A) socket
Remotely controlled sockets 2 groups of 1 x IEC C13 (10 A) 2 groups of 2 x IEC C13 (10 A)
Additional outputs 4 FR/Schuko sockets or 3 BS sockets
with HS MBP or 6 IEC 10A sockets or terminal blocks (HW version)
Additional outputs with FlexPDU
8 FR/Schuko sockets or 6 BS sockets or 12 IEC 10A sockets
Batteries
Typical backup times for 50 and 70% of the VA
Evolution/Evolution S
9/6 mn 16/7 mn 14/7 mn 14/7 mn 14/7 mn 20/14 mn 14/9 mn 17/ 11 mn 15/10 mn
Evolution S + 1 EXB
- 105/60 mn 60/36 mn 85/55 mn 60/42 mn
Evolution S + 4 EXB
-
300/200 mn 180/115 mn 290/200 mn 210/135 mn
Battery management Automatic weekly test (period adjustable), automatic recognition
of external battery units => continuous maximisation of backup time
+ deep discharge protection
Interfaces
Communication ports 1 USB port + 1 RS232 serial port and relay contacts
(3)
+ 1 mini terminal block for remote ON/OFF and Remote Power Off
Communications card slots 1 slot for NMC Minislot 2006 card (included in Netpack versions)
or NMC ModBus/JBus or MC Contacts/Serial
Operating conditions, standards and approvals
Operating temperature 0 to 35°C 0 to 40°C
Noise level < 40dbA < 45 dBA < 50 dBA
Performance - Safety - EMC
IEC/EN 62040-1-1 (Safety), IEC/EN 62040-2 EN 50091-2 class B (EMC), IEC/EN 62040-3
(Performance), IEC/EN 61000-4-2, 61000-4-3, 61000-4-4; 61000-4-5, 61000-4-6, 61000-4-8 (EMI)
Approvals CE, CB report , TÜV
Dimensions (WxDxH) in mm / Weight in kg
Dimensions of the Tower
147*418*234 147*492
*234 440*634*86,2 (RT2U)
Dimensions of the Rack
438*366 438*512*43,2 (1U) 438*556
440*509*86,2 (2U)
440*484*130,7 (RT3U)
*43,2 (1U) *43,2 (1U)
Weight of the Tower/Rack 8,4/ 10,85/ 12,5/ 16,53/ 25,7 24,3 26,6 33,8
33,8 (RT2U)
10,1 16,1 16,6 20
34,3 (RT3U)
Dimensions of EXB
- 440*509*86,2 (2U) 440*484*130,7 (3U)
Weight of the EXB - 30,4 41,7
Evolution 1550
Evolution S 3000 RT2U Netpack
Page view 1
1 2

Comments to this Manuals

No comments